2 Piece Trim Collar 90 Degree
The trim collars are used to give an aesthetic finish where the chimney penetrates the wall of a building. The 90 version is used on horizontal penetrations with a 45 version being used in combination with a 45 tee connection.
- Weathers the building where flue passes through the wall
- Provides a neat finish internally
- Retrofit
- Available in stainless steel and black
Description
Our Eco ICID range has evolved into a multi-application system adaptable for Dry (D), Fu (W) and even Positive Pressure (P) applications.
ICID Plus is ideal not only for traditional stoves but also for pellet stoves, biomass appliances, mini/micro CHP and even condensing boilers capable of withstanding positive pressure.
The system is designed so that the outer case is load bearing and the inner liner is free to expand independently, therefore thermal expansion is accommodated within each and every joint of the system.
ICID Plus comes with a Lifetime Guarantee*
ICID Plus has a number of features:
- Joint designTwist-lock bayonet jointing system. Secured by locking band.
- Advanced corrosion resistant design and construction uses laser welded 316L stainless steel inner liner and stainless steel case.
- The 25mm of high density mineral wool insulation maintains flue gas temperature, maximising efficiency, improving flue draught on start up and minimising condensation.
- Low external case temperature.
- The inner liner is free to expand through the female collar, allowing for maximum thermal expansion even during a soot fire.
- The inner liner has an an engineered design with an inward bead at the female end which acts as a capillary break preventing moisture being drawn through the joint.
- Lip seal packs are available containing a quick fit female lip seal with a grease sachet to allow product to be easily adapted for use in Positive Pressure (P) app.
Exciting news from Schiedel Chimney Systems for Stove and Chimney Installers!
Whenever you register an installation with our easy to use, online guarantee registration portal, you will now accrue points based on the number of installations and installation type.
Once you have reached a minimum of 25 points, you can begin to redeem them for £25 Love2Shop vouchers.
So start to register your installations, taking full advantage of our Lifetime Guarantee on Flex and ICID, as well as guarantees on all our other ranges, and to commence earning points 🙂
Click here for more details.
Guarantee
We are confident in our products and so offer you (the owner) a generous guarantee in relation to the ICID system (the System). Provided that you comply in full with Your Responsibilities (below) and subject to the Small Print (below), we guarantee to you that the System will be free from defects for whichever is the greater of:
- a period equal to the guarantee period of the appliance to which the Liner is first connected; or
- 20 years.
For example, if your System is fitted to an appliance with a guarantee period of 10 years, we will still guarantee your System for 20 years.
In the unlikely event that the System becomes defective during the guarantee period, we will provide a like-for-like replacement for free (subject to your compliance with Your Responsibilities and subject to the Small Print). If the same model is no longer available, we will replace it with a suitable alternative.
When we say ‘no quibbles’ we mean it and so the guarantee we offer is a straightforward one; we’ve set out below what is covered and what isn’t by the guarantee as well how to ensure you benefit from it.
Click here to download the full set of responsibilities of the guarantee.
Click here to register your guarantee for this product.
ICS Plus Approvals and Technical Details
|
ICS |
ICS Plus |
ICS 5000 |
Fuel |
Gas, Oil, wood, coal |
Gas, oil |
Deisel generators, gas, oil |
Firing temp |
450°C |
160°C |
– |
Continuous Firing temp |
– |
– |
540°C |
Short Firing temp |
550°C |
200°C |
760°C |
Thermal Shock |
1000°C |
– |
1100°C |
Mode of Operation |
Zero & negative pressure |
Positive pressure |
Positive, zero & negative pressure |
Pressure Capabilities |
40Pa |
200Pa |
5000Pa (for higher pressure applications consult Rite-Vent Technical Department) |
Fire Rating |
4 Hours Fire Rating to BS 476 Part 20 |
Outer Case |
304 : 1.4301 : X5CrNi 18-10 |
Outer Case Thickness |
0.6mm |
0.6mm (150 – 455mm dia.) 0.7mm (505 – 605mm dia.) |
Seam |
Laser or inert gas welded |
Liner |
316L : 1.4404 : X2CrNiMo 17-12-2 |
Liner Thickness (mm) |
0.5mm |
0.6mm |
Insulation |
High performance mineral fibre |
Insulation Thickness |
25mm (50, 75, 100 available) |
25mm |
Average Thermal Resistance (200°C) |
0.508m² k/w |
Approvals
ICS is CE Certified to EN1856-1 TÜV 0036 CPR 9195 001 with designations:
ICS is CE Certified to EN1856-2 TÜV 0036 CPR 9195 041 with designations:
System Chimney EN1856-1
Connecting Flue Pipe EN1856-2
T450 N1 D V2 L50050 G100 M
T450 N1 W V2 L50050 G60
T450 N1 D V3 L50050 G60
60mm Distance to combustibles in a combustible shaft*
T450 N1 W V2 L50050 G50
T450 N1 D V3 L50050 G50
50mm Distance to combustibles in a non combustible shaft or in free air*
T200 P1 W V2 L50050 O00
Zero distance to combustibles*
• Kitemarked to BS4543 Parts 2 & 3 for gas, oil and solid fuel (Ø 80mm – 200mm inclusive)
• Manufactured under a Quality Management Scheme approved to BS EN ISO 9001
• 4 Hour Fire Rating to BS476 Part 20
• Certified for corrosion resistance on gas, oil and solid fuel by Gastec, MPA and TÜV
• HETAS listed for use on solid fuel applications.
Technical Data |
Fuel |
Wood, solid fuel | With Lip Seal: Gas and oil |
Firing Temp |
450°C | With Lip Seal: 200°C |
Short Firing Temp |
550°C | With Lip Seal: 250°C |
Thermal Shock |
1000°C |
Mode of Operation |
Zero & negative pressure | With Lip Seal: Positive pressure |
Pressure Capabilities |
40Pa | With Lip Seal: 200pa |
Fire Rating |
4 Hour Fire Rating to BS 476 Part 20 |
Outer Case |
Stainless Steel |
Outer Case (Option) |
Painted matt black |
Outer Case Thickness |
0.5mm |
Seam |
Laser or inert gas welded |
Liner |
316L : 1.4404 : X2CrNiMo 17-12-2 |
Liner Thickness (mm) |
0.5mm |
Seam |
Laser or inert gas welded |
Insulation |
High performance mineral fibre |
Insulation Thickness |
25mm |
Average Thermal
Resistance (200°C) |
0.4m2 k/W |
DimensionsThe dimensions of the flue are:
Int Ø mm |
100 |
125 |
150 |
180 |
200 |
Ext Ø mm |
150 |
180 |
200 |
235 |
256 |
Approvals
ICID Plus is CE Certified to EN1856-1 TÜV 0036 CPR 9195 010 with designations:
ICID Plus is CE Certified to EN1856-2 TÜV 0036 CPR 9195 042 with designations:
System Chimney EN1856-1
T450 N1 W V2 L50050 G60
T450 N1 D V3 L50050 G60
60mm Distance to combustibles in a combustible shaft*
T450 N1 W V2 L50050 G50
T450 N1 D V3 L50050 G50
50mm Distance to combustibles in a non-combustible shaft or in free air*
Zero distance to combustibles*
Connecting Flue Pipe EN1856-2
T450 N1 D V2 L50050 G100 M
- Manufactured under a Quality Management Scheme approved to BS EN ISO 9001
- 4 Hour Fire Rating to BS476 Part 20
- Certified for corrosion resistance on gas, oil and solid fuel by Gastec, MPA and TÜV
- HETAS listed for use on solid fuel applications.
Mandatory Requirements
Connection to an appliance which is not connected to the fuel supply, should be carried out by a competent person. We recommend the use of HETAS approved installers for solid fuel applications. If installation is carried out by a non HETAS registered installer, the installation must be certified by a local Building Control inspector. Connection to an appliance that is connected to the fuel supply must be carried out by a Gas Safe (Gas) or OFTEC (Oil) registered installer.
The design guide must be read in conjunction with the detailed component installation instructions. For full design and installation details the key referral documents are:
- BS EN 1856-1: Chimneys – System Chimney Products
- BS EN 1856-2: Connecting Flue Pipes
- BS EN 1859: Metal Chimneys – Testing Methods
- BS EN 1443: Chimneys – General Requirements
- BS EN 15287-1: Chimneys. Design, installation and commissioning of chimneys. Chimneys for non-room sealed heating appliances.
- BS 5440-1: Fluing and ventilation for gas appliances of rated input not exceeding 70kW net (1st,
2nd and 3rd family gases). Specification for installation of gas appliances to chimneys and for maintenance of chimneys.
- Approved Document J: – Combustion appliances and fuel storage systems (England & Wales)
- DFP Technical Booklet L: – Combustion appliances and fuel storage systems (NI)
- Technical Handbook (Domestic & Non Domestic), Section 3 – Environment (Scotland)
- Appliance Installation Instructions and related standards. Other standards covering specific applications will also be relevant and must be adhered to.
Planning permission may be required, and reference should be made to the local Building Control Department.
Ensure all chimney components are available and check them to ensure there has been no damage. Do not use damaged components. Build the chimney up through the previous designed route which should be as straight as possible.
We have various photos of our products available on flickr. Please click here to visit our page, where you will also find images of our HETAS Approved Schiedel Training Academy, as well as examples of our products in Residential and Commercial situations.
We are featured in various online and offline publications, with articles about our products, installation examples and much more, including distributors of our range. Visit our Pinterest page to see more.
Schiedel TV Channel
Visit our YouTube channel, where you fill find a number of useful videos guides and installation instructions, as well as a number of videos showing how are steel products are made within our manufacturing base in the North East of England.